Reference Manual
00809-0100-4811, Rev DA
Section 3: Installation
January 2015
Installation
3.5.3 Threaded tank connection
Figure 3-13. Threaded Tank Connection
1. For tank connections with BSP/G threads, place a gasket on top of the tank flange, or
use a sealant on the threads of the tank connection.
2. Lower the transmitter and probe into the tank.
3. Screw the adapter into the process connection.
4. Loosen the nut that connects the transmitter housing to the probe slightly.
5. Rotate the transmitter housing so the cable entries/display face the desired direction.
6. Tighten the nut.
Note
For adapters with NPT threads, pressure-tight joints require a sealant.
D
C
A
B
A Tank connection
B Probe
C Nut
D Sealant on threads or gasket (for BSP/G threads)